Lun-Hsiang Yuan MD, PhD中文
Prostate · Jul 29, 2026

Evaluation of Diagnostic Performance and Inter-Reader Agreement of Prostate Imaging After Focal Ablation (PI-FAB) on Post-Focal Therapy (FT) Magnetic Resonance Imaging (MRI)

PI-FAB may standardize post-cryoablation surveillance, but prospective validation is still needed.

Lun-Hsiang Yuan, MD, PhD · 4 min read

Graphic summary of the paper: Evaluation of Diagnostic Performance and Inter-Reader Agreement of Prostate Imaging After Focal Ablation (PI-FAB) on Post-Focal Therapy (FT) Magnetic Resonance Imaging (MRI)

Key points

  • This retrospective study evaluated 85 post-focal cryoablation patients and 140 lesion sites with post-FT mpMRI and biopsy.
  • Reader 1 achieved 83.9% sensitivity, 84.4% specificity, 60.5% PPV, and 94.8% NPV.
  • Reader 2 achieved 71.4% sensitivity, 87.5% specificity, 58.8% PPV, and 92.5% NPV.
  • Both readers had 84.3% accuracy, with moderate inter-reader agreement (κ = 0.60).

Review

Post-focal therapy surveillance for localized prostate cancer is challenging because focal ablation alters prostate architecture on follow-up multiparametric MRI. PI-FAB was developed as a three-point system to standardize assessment of in-field recurrence after focal ablation. This retrospective study included 85 patients and 140 lesion sites from October 2019 to January 2024 after focal cryoablation, all with post-FT mpMRI and biopsy. Two radiologists with 11 and 4 years of experience independently scored mpMRI using PI-FAB. Diagnostic metrics included sensitivity, specificity, PPV, NPV, and accuracy; inter-reader agreement was measured with quadratic weighted Cohen’s kappa. Reader 1, the more experienced reader, achieved 83.9% sensitivity, 84.4% specificity, 60.5% PPV, and 94.8% NPV for in-field recurrence. Reader 2 achieved 71.4% sensitivity, 87.5% specificity, 58.8% PPV, and 92.5% NPV. Accuracy was 84.3% for both readers, and inter-reader agreement was moderate at κ = 0.60. The authors interpret these findings as supporting good diagnostic performance of PI-FAB after cryoablation, with moderate reproducibility across experience levels, while noting that reader experience may affect sensitivity. Clinically, the high NPV is particularly relevant for surveillance discussions, but the evidence remains retrospective, based on 85 patients, and specific to post-cryoablation assessment; prospective and external validation are needed before PI-FAB can be treated as a definitive management tool.

Clinical Significance

The main clinical value is a standardized framework for interpreting mpMRI after focal cryoablation, with high NPV values of 92.5%–94.8% that may help contextualize in-field recurrence risk during surveillance. However, this is retrospective diagnostic-performance evidence in 85 patients and should be considered supportive and hypothesis-generating, not a stand-alone determinant of biopsy or treatment decisions.